Complex stenting of an obstructed outflow graft of a heartmate 3 in an adult after a mustard procedure

Published online by Cambridge University Press:  14 July 2025

Daiji Takajo*
Affiliation:
Heart Institute, Cincinnati Children’s Hospital Medical Center, OH, USA
Amr Matoq
Affiliation:
Heart Institute, Cincinnati Children’s Hospital Medical Center, OH, USA
Angela Lorts
Affiliation:
Heart Institute, Cincinnati Children’s Hospital Medical Center, OH, USA
Russel Hirsch
Affiliation:
Heart Institute, Cincinnati Children’s Hospital Medical Center, OH, USA Department of Pediatrics, College of Medicine, University of Cincinnati, OH, USA
*
Corresponding author: Daiji Takajo; Email: dt1449@gmail.com

Abstract

Ventricular assist devices, such as the HeartMate 3, are routinely used to support patents with failing ventricular function. However, extrinsic obstruction of the outflow graft has been identified as a complication associated with the HeartMate 3. We report a case of a patient with transposition of the great arteries (d-TGA), status post-Mustard procedure with severe systemic (right) ventricular dysfunction who developed extrinsic obstruction of theoutflow graft, 6 years after implant, leading to a significant reduction in HeartMate 3 flow. This patient required the placement of multiple stents to fully address the diffuse stenosis of the outflow graft. This case underscores the technical challenges involved in managing extrinsic obstruction of theoutflow graft in patients with this anatomy and highlights the importance of a tailored, multidisciplinary approach. It emphasises the need for careful planning around stent overlap, outflow graft angulation, and catheter and wire positioning in the context of complex anatomical and device-related interactions.

Information

Type
Case Report
Copyright
© The Author(s), 2025. Published by Cambridge University Press

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

Article purchase

Temporarily unavailable

References

Maly, J, Netuka, I, Besik, J, Dorazilova, Z, Pirk, J, Szarszoi, O. Bridge to transplantation with long-term mechanical assist device in adults after the Mustard procedure. J Heart Lung Transplant 2015; 34 ( 9 ): 11771181. DOI: 10.1016/j.healun.2015.03.025.10.1016/j.healun.2015.03.025CrossRefGoogle ScholarPubMed
Administration USFaD. Abbott/Thoratec Corp. recalls HeartMate II and HeartMate 3 left ventricular assist system (LVAS) due to potential risk of outflow graft twisting or long-term buildup causing an obstruction. Updated 04/15/2024. Accessed 12/9, 2024. https://www.fda.gov/medical-devices/medical-device-recalls/abbottthoratec-corp-recalls-heartmate-ii-and-heartmate-3-left-ventricular-assist-system-lvas-due#:∼:text=Medical%20Device%20Recalls-,Abbott%2FThoratec%20Corp.,term%20Buildup%20Causing%20an%20Obstruction&text=Please%20be%20aware%2C%20this%20recall,most%20serious%20type%20of%20recall. Google Scholar
Goldstein, DJ, Kanwar, M, Cowger, J, et al. Extrinsic outflow graft obstruction of the HeartMate 3 LVAD: a state-of-the-art review. J Heart Lung Transplant 2024; 43 ( 11 ): 18731880. DOI: 10.1016/j.healun.2024.07.005.10.1016/j.healun.2024.07.005CrossRefGoogle ScholarPubMed
Kar, B, Delgado, RM, 3rd, Frazier, OH, etal. The effect of LVAD aortic outflow-graft placement on hemodynamics and flow: implantation technique and computer flow modeling. Tex Heart Inst J 2005; 32 ( 3 ): 294298.Google ScholarPubMed
Supplementary material: File

Takajo et al. supplementary material

Takajo et al. supplementary material
Download Takajo et al. supplementary material(File)
File 55.6 MB